ASCO電磁閥8223G010
二位兩通高壓不銹鋼電磁閥
美國ASCO阿斯卡
簡單介紹
ASCO二位兩通高壓不銹鋼電磁閥位二通電磁閥二位二遁電磁閥適用于以蒸汽為加熱介質(zhì)的加熱器、散熱器、 干燥機(jī)及紡織定型機(jī)、蒸染機(jī)、**真空回潮機(jī)、蔬菜烘干機(jī)等成套設(shè)備的蒸汽管跟進(jìn)行二位式自動和遠(yuǎn)程通斷切換
接口尺寸: G1/2壓力: 25-1500psi類型(通道位置) :先導(dǎo)式
標(biāo)準(zhǔn):美標(biāo)公稱通徑: ASCO(mm)工作溫度:常溫
實(shí)現(xiàn)溫度自動控制。電磁閥選用于以水或液體為工作介質(zhì),
可自動控制或遠(yuǎn)程控制水、油、液體等工作介質(zhì)管路的通斷。
由于本閥采用橡膠密封,故對工作介質(zhì)的清潔度大大減低,
具有啟閉迅速.可靠性高等優(yōu)點(diǎn)。電磁閥為二次開閥的先導(dǎo)式電磁閥 ,其結(jié)構(gòu)主要由導(dǎo)閥和主閥組成,
材質(zhì):鑄鋼流動方向:換向通口數(shù)量:兩位兩通常閉
壓力環(huán)境:低壓零部件及配件:配件
形態(tài):角式規(guī)格:代替型號8223G003 (銅) ,線國238610-158-D AC220V,
線園238710 DC24V,線國等級MP-C-080,閥體240523-001-F,WP-C-080連接形式:螺紋
品牌:ASCO適用介質(zhì):蒸汽用途:鎖閉
電磁閥應(yīng)保證在電源電壓為額定電壓的15%-10%波動范圍內(nèi)正常工作。
3.電磁閥安裝后,管道中不得有反向壓差。并需通電數(shù)次,
使之適溫后方可正式投入使用。4. 電磁閥安裝前應(yīng)徹底清洗管道。
通入的介質(zhì)應(yīng)無雜質(zhì)。閥前裝過濾器。5、 當(dāng)電磁閥發(fā)生故障或清洗時,
為保證系統(tǒng)繼續(xù)運(yùn)行,應(yīng)安裝旁路裝置。6. 接管時注意。
密封材料不可使用過量,如螺紋連接時,接管外螺紋長度不可超過電磁閥內(nèi)螺紋的有效長度,
并在外螺紋前端半摞距處用銼刀倒棱,自螺紋2牙處開始纏繞密封
ASCO solenoid valve
Two position two way high-pressure stainless steel solenoid valve
Product model: 8223G010
Product exhibitor: ASCO Asca, USA
A brief introduction
Hot selling ASCO two position two way high-pressure stainless steel solenoid valve two position two way solenoid valve two position two escape solenoid valve suitable for steam heating
Medium heaters, radiators, dryers, textile shaping machines, steaming and dyeing machines, vacuum humidifiers, vegetable dryers, etc
The steam pipes of the complete equipment can be switched between two automatic and remote on-off modes,
Interface size: G1/2 Pressure: 25-1500psi Type (channel position): Pilot operated
Standard: American standard, nominal diameter: ASCO (mm), working temperature: room temperature
Realize automatic temperature control. Electromagnetic valves are selected for use with water or liquid as the working medium,
It can automatically control or remotely control the on-off of working medium pipelines such as water, oil, and liquids.
Due to the use of rubber seals in this valve, the cleanliness of the working medium is greatly reduced,
It has the advantages of fast opening and closing, high reliability, etc. The solenoid valve is a pilot operated solenoid valve with a secondary opening, and its structure mainly consists of a pilot valve and a main valve,
Material: Cast steel Flow direction: Reversing port Quantity: Two positions Two normally closed
Pressure environment: Low pressure components and accessories: Accessories
Form: angled specification: replaces model 8223G003 (copper), wire country 238610-158-D AC220V,
Wire park 238710 DC24V, wire national grade MP-C-080, valve body 240523-001-F, WP-C-080 connection form: threaded
Brand: ASCO Applicable medium: Steam Purpose: Locking
The solenoid valve should ensure normal operation within a fluctuation range of 15% -10% of the rated voltage of the power supply.
3. After the installation of the solenoid valve, there should be no reverse pressure difference in the pipeline. And it needs to be powered on several times,
It can only be officially put into use after being warmed up. 4. Before installing the solenoid valve, the pipeline should be thoroughly cleaned.
The medium introduced should be free of impurities. Install a filter in front of the valve. 5. When the solenoid valve malfunctions or is cleaned,
To ensure the continued operation of the system, a bypass device should be installed. 6. Pay attention when taking over.
Sealing materials should not be used excessively. For example, when connecting with threads, the length of the external thread of the connecting pipe should not exceed the effective length of the internal thread of the solenoid valve,
And use a file to chamfer the front half distance of the external thread, and start wrapping the sealing tape from the second tooth of the thread